Dual-pressure valve
Valve operation
This two way valve offers two pressure settings at the user port: system pressure or regulated pressure (0-3 bar) by adjusting screw R.
A three way directional control valve must be fitted downstream of this valve if the circuit is required to exhaust.
The regulated pressure can be read by connecting a manometer at point M.
The valve is available either electrically or pneumatically operated, "normally closed".
NORMALLY CLOSED
Without signal at point X the output is regulated pressure.
- 00.047.4 Normally closed, pneumatically piloted
- 00.008.3 Normally closed, solenoid actuated
Technical data
- Ports: G1/8"
- Temperature range: max +60°C
- Working pressure: 2.5 ... 10 bar
- Adjustable pressure range (screw R): 3 ... 10 bar
- Fluid: 50µ filtered, lubricated or non lubricated air
Materials
- Body: aluminium 11S
- Seals: NBR
- Springs: stainless steel
- Spools: nickel plated aluminium
- Internal parts: brass OT58
Flow rates